Fault phenomenon | Possible cause | Overhaul method |
Do not work after turning on the power supply, no indication of work indicator | 1. The power supply is not on or in bad contact 2. The circuit breaker in the control box is not closed 3. Fuse damage of controller | 1. Connect the power supply, deal with the bad part 2. Close the circuit breaker 3. Find the cause, replace the mental fuse. |
No automatic operation | 1. The automatic working switch is not on or out of order 2. Sensor lines or not well connected. Sensor adjusting distance is too close | 1. Overhaul or replace automatic switch 2. Reconnect line 3 according to wiring diagram. Readjusting the effective distance of the sensor |
To keep repeating empty movements | 1. Sensor wiring error 2. Manual start button bad | 1. Readjust sensor effective range 2. Reconnect line 3 according to wiring diagram. Replace maintenance manual start button |
Electric electrodes or electric trolleys can not work | 1. The pressure is too low by two. Solenoid valve has no voltage (220v) 3. Mechanical moving parts jammed or rusted to death | 1. Adjust the gas pressure 2. Check solenoid valve coil and connection line 3. Repair or replacement of faulty parts |
No voltage output during electric shock | 1. The hemp switch was not turned on. The electric voltage in the control box is not adjusted 3. Electric shock plate connection line broken | 1. Turn on the electric switch 2. Recalibrate the electric voltage of the anesthesia 3. Reconnect the plate circuit |
Manual failure to work | 1. Manual start button damaged 2. Stop button damaged 3. Damage to control button of electric trolley | 1. Replace or maintain start button 2. Replace or repair stop button 3. Replacement or maintenance of car control buttons |